BX695A/BX704A O/P transformer (Algemeen)
Dear Friends
In the service manual of BX695A the D.C resistance of the O/P transformer primary winding indicates 3200 ohms of each half. Whereas in the service manual of BX704A it shows 330 Ohms of each half. Is there some mistake in the resistance shown in the service manual because normally the resistance of the primary winding is around 300 ohms each half for the sets with EL41 in Push Pull.
Best Regards
P.Rajan
Berichten in deze thread:
- BX695A/BX704A O/P transformer -
Pandu Rajan,
30.03.2021, 09:46
- BX695A/BX704A O/P transformer -
Robert Gribnau,
30.03.2021, 10:14
- BX695A/BX704A O/P transformer - Pandu Rajan, 30.03.2021, 16:24
- BX695A/BX704A O/P transformer -
Robert Gribnau,
30.03.2021, 10:14